    High definition China Kerong High Quality Reverse Engineering Services Project One Stop PCB Board Design Layout Service and Software Development

    Rectifier module adopts the international forefront PTR soft switch technology with high efficiency and reliability. The unique deep discharge capacity makes the lead-acid battery have more than three times of service life when on EPO emergency startup.
    Using the latest fire prevention corrosion resistant material with professional fire prevention safety design to keep away from fire hazards.
    Easy to maintain, can be monitored by computer, automaitic switch between external power grid and the battery, unattended operation, mutual switch time ≤0.25S.
    Smart battery management: can adjust number of batteries, battery voltage (upper and lower limits), set the battery failure recovery voltage (upper and lower limits), set up regular battery testing, the battery voltage, battery failure alarm, etc.

    Read More>>


    Product Detail

    Product Tags

    Overview

    It can be divided into AC output (JC-D)和DC output(ZC-D), and provide emergency power to keep system normal working for evacuation lighting and indicator lights when in lack of city power. This centrally connected power source is DC output type with 220VAC/216VDC (216VDC when in emergency).
    Features
    1、Rectifier module adopts the international forefront PTR soft switch technology with high efficiency and reliability. The unique deep discharge capacity makes the lead-acid battery have more than three times of service life when on EPO emergency startup.
    2、Using the latest fire prevention corrosion resistant material with professional fire prevention safety design to keep away from fire hazards.
    3、Easy to maintain, can be monitored by computer, automaitic switch between external power grid and the battery, unattended operation, mutual switch time ≤0.25S.
    4、Smart battery management: can adjust number of batteries, battery voltage (upper and lower limits), set the battery failure recovery voltage (upper and lower limits), set up regular battery testing, the battery voltage, battery failure alarm, etc.

    Technical Index

    Centrally connected power source

    ZC- D-2KVA

    ZC- D-3KVA

    ZC- D-5KVA

    ZC- D-7.5KVA

    Input

    voltage

    Single phase 220V(1±25%)

    frequency

    50Hz ((1±5%))

    Output

    voltage

    24VDC (30-50A)

    Battery

    type

    Sealed maintenance free

    nominal voltage

    216VDC

    charge time

    <24H

    Switch time

    <2s

    Emergency power supply time

    Normal: 90min

    Load ability

    120% 60s; 150% 5s

    Protection function

    Circuit breaker, lack voltage, over current, short circuit

    Noise (1M)

    When city power normal and emergency: no noise

    Working environment

    humidity

    10%-90%

    temperature

    -10?℃-40?℃

    altitude

    <2000m

    Adaptive load

    Adapt to all high/low voltage DC (216VDC/24VDC)lighting load

    Output circuit (standard type)

    4

    Standard size

    750mm*410mm*1500mm

    800mm*600mm*2000mm

    Outer size

    ?201707030311264872 ?201707030311337216